仕様一覧
-
サンプリングプローブ適合性
Raman Rxn-10プローブ
アプリケーション
Paired with the Rxn-10 probehead, Raman non-contact optics provide contact-free Raman measurements of samples either directly or through sight glass or translucent packaging. Available with a range of working distances, these highly versatile optics are the perfect choice for use with solids or turbid media. They are also well suited for delicate or corrosive samples when sample contamination or damage to optical components is a concern.
Pharmaceutical: Drug product manufacturing
Chemical: Polymer solids (pellets, films, or powders)
Food & Beverage: Meat or fish quality
Raw material identification
Formulation optimization
利点
Range of working distances for remote measurements either directly or through sight glass and translucent packaging
Highly versatile – measuring films to pellets to powders
Accurate measurement of static or moving samples
Contact-free analysis of delicate or corrosive samples
FLEX セレクション | 技術的卓越性 | シンプルさ |
---|---|---|
Fundamental セレクション 基本的な測定要件に対応 |
技術的卓越性
|
シンプルさ
|
Lean セレクション コアプロセスの要件に対応 |
技術的卓越性
|
シンプルさ
|
Extended セレクション 革新的な技術でプロセスを最適化 |
技術的卓越性
|
シンプルさ
|
Xpert セレクション 最も困難なアプリケーションにも対応 |
技術的卓越性
|
シンプルさ
高い柔軟性 |
-
-
技術仕様書(TI)
Accessory Optics for the Rxn-10 Probe Technical Information
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)EN JA 31/05/202303/08/2022言語:
英語
バージョン:
31/05/2023
ファイルサイズ:
467.9 KB
ファイル名:
TI01635CEN_0322.pdf
-
-
-
技術仕様書(TI)
Rxn-10 Raman Spectroscopic Probe Technical Information
System design and specifications
for the Raman Rxn-10 probe言語:
英語
バージョン:
31/05/2023
ファイルサイズ:
423 KB
ファイル名:
TI01629CEN_0322.pdf
-
-
-
取扱説明書(BA)
Accessory optics for the Rxn-10 Probe Operating Instructions
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)EN JA 31/05/202303/08/2022言語:
英語
バージョン:
31/05/2023
ファイルサイズ:
1.8 MB
ファイル名:
BA02171CEN_0322.pdf
-
-
-
取扱説明書(BA)
Rxn-10 Raman Spectroscopic Probe Operating Instructions
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe言語:
英語
バージョン:
31/05/2023
ファイルサイズ:
1.2 MB
ファイル名:
BA02160CEN_0322.pdf
-
-
-
簡易取扱説明書(KA)
Rxn-10 Raman Spectroscopic Probe Brief Operating Instructions
Quick start guide for the Raman Rxn-10 probe
言語:
英語
バージョン:
31/05/2023
ファイルサイズ:
895.3 KB
ファイル名:
KA01546CEN_0322.pdf
-
-
-
簡易取扱説明書(KA)
Accessory Optics for the Rxn-10 Probe Brief Operating Instructions
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)EN JA 31/05/202303/08/2022言語:
英語
バージョン:
31/05/2023
ファイルサイズ:
1 MB
ファイル名:
KA01551CEN_0322.pdf
-
-
-
PU(広報)
Raman application guide for the life science industry - Trusted composition analysis for the life sciences
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).言語:
英語
バージョン:
19/04/2022
ファイルサイズ:
1.1 MB
ファイル名:
PU01447CEN_0222.pdf
-
-
-
コンピテンスカタログ(CP)
Raman spectroscopy food & beverage application guide - Trusted technology for composition analysis in a laboratory or process environment
A guide to Raman spectroscopy application notes for the
food & beverage industry (featuring studies using the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe,
Rxn-20 probe, Rxn-45 probe, and the immersion optic
and non-contact optic).言語:
英語
バージョン:
17/02/2022
ファイルサイズ:
859 KB
ファイル名:
CP01489CEN_0122.pdf
-
-
-
イノベーション(IN)
Raman spectrographic probes - Robust optical measurement of chemical composition
An overview brochure about our Raman spectroscopy probe
portfolio including the Rxn-10 probe, Rxn-20 probe, Rxn-30 probe,
Rxn-40 probe, Rxn-41 probe, Rxn-45 probe, Rxn-46 probe, and
probe accessory optics (bIO-Optic, Raman single use optic system /
SUB, immersion optic , non-contact optic), powered by Kaiser Raman
technology.言語:
英語
バージョン:
26/10/2021
ファイルサイズ:
4.9 MB
ファイル名:
IN01225CEN_0121.pdf
-
-
-
ホワイトペーパー (WP)
How Raman ensures product quality from lab-to-process in biopharma
A whitepaper about using Raman spectroscopy for lab-to-process
chemical composition measurement in biopharmaceutical manufacturing
(applicable to the Endress+Hauser Raman analyzer and probe
bioprocessing portfolio, powered by Kaiser Raman technology
(including the Raman Rxn2 analyzer, Raman Rxn4 analyzer,
Rxn-10 probe, Rxn-45 probe, Rxn-46 probe, bIO-Optic, Raman
single use optic system, immersion optic , non-contact optic).言語:
英語
バージョン:
17/02/2022
ファイルサイズ:
350.8 KB
ファイル名:
WP01172CEN_0222.pdf
-