Omnigrad M TW11
Protection tube for temperature sensors

Omnigrad M TW11 ©Endress+Hauser

Designed for use in the fine chemicals industry and generally for almost all industrial processes

This protection tube is an important component for temperature measurement points for almost all industrial processes, especially for fine chemicals industries. It is used to protect the measuring insert or sensor elements from aggressive process media, high pressures and flow rates from the temperature sensor itself and thereby enables the thermometer to be exchanged during operation.

  • 利点

    • Tip of the thermowell with a reduced diameter or tapered for a faster response time

    • Customized immersion length

    • Surface finishing Ra < 0.8 μm

    • SS 316L/1.4404 and SS 316Ti/1.4571 for the "wetted" parts

    • The common threaded process connections are supplied as...

  • アプリケーション

    Omnigrad M TW11 protection tubes are designed for the use in the fine chemicals industry but can also be used for generic applications.

機能と仕様

戻る

Details

  • 測定原理

    組立形(パイプ封じ径)サーモウェル

  • 特性 / アプリケーション

    メートル法

    DIN 43772 Form 2/3

    ネジ込みプロセス接続

    ネックなし

  • 接続部ヘッド

    雄ネジ:

    M24 x 1.5

    1/2" NPT

  • 最大標準浸漬長

    4,000 mm (157.48")

  • 最大浸漬長 要問合わせ

    10,000 mm (393.7")

  • プロセス接続

    ネジ:

    G3/8"

    G1/2"

    G3/4"

    1/2" NPT

    3/4" NPT

    R1/2"

    R3/4"

    R1"

    M20 x 1.5

  • 谷径

    9 mm(0.35")

    11 mm(0.43")

    12 mm(0.47")

    14 mm(0.55")

    15 mm(0.59")

  • 様々な測定物に対応した材質

    1.4401(SUS316相当)

    1.4404(SUS316L相当)

    1.4571(SUS316Ti相当)

  • 接液部仕上げ(Ra)

    < 0.8 ìm (31.50 ìin)

  • 先端チップ部の形状

    ストレート

    切詰

    テーパー

  • 温度レンジ

    -200...700 °C (-328...1,292 °F)

  • 最大プロセス圧力 (静的)

    5 MPa (725 psi)

  • 最大プロセス圧力 (400℃の時)

    プロセス接続に依存

ドキュメント/マニュアル/ソフトウェア

アクセサリ / スペアパーツ

Nr
Order code
Specification