Omnigrad M TR10
Modular RTD thermometer

Omnigrad M TR10
Modular RTD thermometer ©Endress+Hauser
Omnigrad M TR10
Modular RTD thermometer ©Endress+Hauser
Omnigrad M TR10
Modular RTD thermometer ©Endress+Hauser

Comprehensive and common temperature measurement technology for almost all branches of industry

The high modular and robust thermometer finds its use in several applications in almost all industries. An optional head transmitter, with all common communication protocols, makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. A variety of process connections, dimensions and materials offer flexible application possibilities.

クイック選択

推奨オプションから選択
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

または

個別のコンフギュレータ

すべての使用可能なオプションから選択を続行
  • 利点

    • High degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion lengths

    • High degree of insert compatibility and design as per DIN 43772

    • Extension neck to protect the head transmitter...

  • アプリケーション

    • Universal range of application

    • Measuring range: -200 to +600 °C (-328 to 1112 °F)

    • Pressure range up to 75 bar (1088 psi)

    • Degree of protection: up to IP68

    • Vibration-resistant sensor elements up to 60g

機能と仕様

戻る

Details

  • 測定原理

    測温抵抗体

  • 特性 / アプリケーション

    メートル法

    モジュラータイプ

    汎用アプリケーション

    危険場所に最適

    ネジ込みプロセス接続

    ネックあり

    サーモウェル/保護管(金属製)付き

    挿入用StrongSensと併用可能

  • サーモウェル / 保護管

    溶接保護管

  • インサート / プローブ

    無機絶縁 (MI)、形状変更可

  • 保護管/インサート外径

    9.0 mm(0.35'')

    11.0 mm(0.43'')

    12.0 mm(0.47'')

    14.0 mm(0.55")

    15.0 mm(0.59")

  • 最大浸漬長 要問合わせ

    最大10,000.00 mm(393.70'')

  • 保護管/サーモウェルの材質

    1.4404(SUS316L相当)

    1.4571(SUS316Ti相当)

    アロイ C276(2.4819)

    アロイ 600(2.4816)

  • コーティング(オプション)

    定義されていません

  • プロセス接続

    雄ネジ:

    G1/2"

    G3/4"

    G1"

    NPT1/2"

    NPT3/4"

    M20x1.5

  • 先端チップ部の形状

    ストレート

    切詰

    テーパー

  • 表面粗さ Ra

    定義されていません

  • 測定温度レンジ

    PT100 TF StrongSens:

    -50~+500 °C

    (-58~+932 °F)

    PT100 WW:

    -200~+600 °C

    (-328~+1,112 °F)

    PT100 TF:

    -50~+400 °C

    (-58~+752 °F)

  • 最大プロセス圧力 (静的)

    20 ℃の時:7.5 MPa (1,088 psi)

  • 精度

    クラス A(IEC 60751基準)

    クラス AA(IEC 60751基準)

  • 応答時間

    設定に依存

  • 組込型伝送器

    あり(4~20 mA;HART;PROFIBUS PA;FOUNDATIONフィールドバス)

  • 防爆認定

    ATEX II

    ATEX IECEx

    NEPSI

    IECEx

    EAC Ex

  • 認証

    Gost 度量衡

    SIL(伝送器のみ)

ドキュメント/マニュアル/ソフトウェア

アクセサリ / スペアパーツ

Nr
Order code
Specification
  • C
  • A
    • Nr A Order code TPR100-

      Insert TPR100

      Mineral insulated cable (MgO). Replaceable insert acc.EN60751. max. measuring range: -200...600oC (depending on configuration).

    • Nr A Order code TS111-

      Insert iTHERM TS111

      Replaceable. Metric version according DIN43735.

  • E
  • B
    • Nr B Order code TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Nr B Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Nr B Order code TID10-

      Display for head transmitter TID10

      to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84, TMT82.

  • D
    • Nr D Order code TA20A-

      Terminal Head TA20A

      Product being phased out, limited availability. Connection head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material: Aluminium epoxy resin coating Area temperature : max. +100 oC; ATEX: +95 oC.

    • Nr D Order code TA20B-

      Terminal Head TA20B

      "Product being phased out, limited availability." Connecting head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material:Polyamid black. Ambient temperature: max. +80 oC. Protection: IP65.

    • Nr D Order code TA20D-

      Terminal head TA20D

      Product being phased out, limited availability. Connection head to mount a measuring insert with up to two head transmitters or a connection socket and one head transmitter. For mounting on armature or protection sleeve. Material: Aluminium, varnished Ambient temperature: max. +100 oC; ATEX: +95 oC. Protection: IP66

    • Nr D Order code TA20R-

      Terminal Head TA20R

      Product being phased out, limited availability. Connecting head to mount a measuring insert with head transmitter or a connection socket. To be mounted on an armature or protective sleeve. Material: AISI316L/1.4404. max temperature 100oC, ATEX: +95oC. Protection class IP66/IP67.

    • Nr D Order code TA20W-

      Terminal head TA20W

      Product being phased out, limited availability. Connection head hinged to mount a measuring insert with head transmitter or connection socket. To be mounted on an armature or a protection sleeve. Material: Aluminium Area temperature: max. +100 oC; ATEX: +95 oC Protection: IP66

    • Nr D Order code TA21E-

      Terminal Head TA21E

      Retainer for terminal block or head transmitter. Cover: srewable. Material: aluminum. Max. temp.: +100 oC; ATEX +95 oC. Protection: IP65.

    • Nr D Order code TA30A-

      Terminal Head TA30A

      Retainer for terminal block or head transmitter + optional display. Cover: low, hinged, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).

    • Nr D Order code TA30D-

      Terminal Head TA30D

      Retainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50...150 oC (housing). Protection: IP66/68, NEMA 4X (housing).

    • Nr D Order code TA30P-

      Terminal Head TA30P

      Retainer for 2 head transmitters or terminal blocks. Cover: high, hinged. Material: Polyamid PA12 antistatic. Colour: black. Ambient temp.: -40...120oC (housing). Protection: IP65 (housing).

    • Order code FXA195-

      Commubox FXA195

      Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.

  • B
    • Nr B Order code TMT182-

      iTEMP TMT182, Head Transmitter HART

      Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr B Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.

  • B
    • Nr B Order code TMT180-

      iTEMP TMT180, Head Transmitter Pt100

      Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr B Order code TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

  • 後継機種