FLOWSIC600-XTには、4、4+1、4+4、8 x 測定パスのバージョンが用意されています。OIML R 137 Class 1.0の要件に加え、FLOWSIC600-XTはClass 0.5およびAGA9の要件も完全に満たしています。FLOWSIC600-XTには、高度なアプリケーション診断機能であるi-diagnostics™と、電源電圧に障害が発生した場合に最大3週間の連続測定運転を実現するPowerIn Technology™が搭載されています。このため、最高クラスの測定精度と長期安定性が保証されます。
Learn how InPipe Energy converts excess pipeline pressure into renewable power using its energy recovery system, supported by Endress+Hauser’s electromagnetic flow technology.
Volumetric flow a. c., volume a. c., gas velocity, Speed of sound, optional volume correction via integrated, electronic volume corrector (EVC)
Measuring Medium
Natural gas (with up to 30% hydrogen), air, natural gases containing increased levels of CO2, N2, H2S, O2, H2
Repeatability
≤ 0.05 % of the measured value (typical)
Accuracy
4-path and 8-path version ≤ ± 0.5 % | (≤ ± 1%) Dry-calibrated
4-path and 8-path version ≤ ± 0.2 % | (≤ ± 0.5%) After flow calibration and alignment using constant factor. Without the calibration uncertainty of the test bench.
4-path and 8-path version ≤ ± 0.1 % | (≤ ± 0.2%) After flow calibration and alignment using polynomial or piecewise correction. Without the calibration uncertainty of the test bench.
Medium temperature range
–46 °C ... +180 °C / -51 °F ... +356 °F On request:–194 °C ... +280 °C / –381 °F ... +536 °F
Operating pressure range
0 bar (g) ... 450 bar (g) 0 psi (g) ... 6527 psi (g)
Nominal pipe size
3 ″ ... 56 ″ (DN 80 ... DN 1400), other nominal pipe sizes on request
Metrological approvals and certificates
OIML R 137-1&2:2012 (class 0.5) OIML D 11:2013 ISO 17089-1 AGA-Report Nr. 9 MID: 2014/32/EU PED: 2014/68/EU ASME: B16.5, B16.47 A/B ATEX: 2014/34/EU EMC: 2014/30/EU GOST 8.611-2013 GOST 8.733-2011 CPA: JJG1030-2007 PCEC: GB 3836.1-2010, GB 3836.2-2010, GB 3836.4-2010, GB/T 3836.22-2017
Hazardous area approvals
IECEx Ex db ia op is [ia Ga] IIA/IIC T4 Gb Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb Ex ia op is IIA/IIC T4 Ga
ATEX II 2 (1) G Ex db ia op is [ia Ga] IIA/IIC T4 Gb II 2 (1) G Ex db eb ia op is [ia Ga] IIA/IIC T4 Gb II 1G Ex ia op is IIA/IIC T4 Ga NEC/CEC (US/CA) Explosion-proof / non-incendive: CI I, Div. 1 Group D, T4 / Ex d ia [ia Ga] IIA T4 Gb / Cl I, Zone 1 AEx d ia op is [ia Ga] IIA T4 Gb CI I, Div. 1 Groups B, C, D, T4 / Ex d ia [ia Ga] IIC T4 Gb / Cl I, Zone 1 AEx d ia op is [ia Ga] IICT4 Gb Intrinsically safe: CI I, Div. 1 Group D T4 / Ex ia IIA T4 Ga / Cl I, Zone 0, AEx ia op is IIA T4 Ga CI I, Div. 1 Groups A, B, C, D, T4 / Ex ia IIC T4 Ga / Cl I, Zone 0, AEx ia op is IIC T4 Ga
Digital Outputs
4 outputs: 2 x status, 2 x pulse: ≤ 30 V, 50 mA Passive, electrically isolated, open collector or conforming to NAMUR (DIN EN 60947-5-6), fmax = 10 kHz(scalable)