Conductive
Point level detection
Pump Protection FTW360

Pump Protection FTW360 ©Endress+Hauser

Compact flush-mounted probe

The FTW360 is made for detection of liquids on the suction side of a pump for dry run protection. It operates in all conductive liquids, sludges and pastes that do not form an insulated build-up on the wall of the piping (e.g. oil film). The unit is also suitable for minimum or maximum detection in tanks.

  • 利点

    • Simple and reliable solution also for adhesive or viscous products

    • Cost-effective probe for conductive liquids

    • Universal electronics for AC and DC voltages

  • アプリケーション

    For detection of liquids on the suction side of a pump for dry run protection. For conductive liquids, sludges and pastes that do not form an insulated build-up on the wall of the piping (e.g. oil film). For minimum or maximum detection in tanks.

    • ...

Details

  • 測定原理

    導電性

  • 特性 / アプリケーション

    ポンプ保護用コンパクトリミットスイッチ、
    付着補償機能、
    フラッシュマウント

  • 特徴

    CIP 洗浄可能

  • 電源 / 通信

    AC 21 ... 253 V
    DC 20 ... 200 V

  • 周囲温度

    -20 °C ... 60 °C
    (-4 °F ... 140 °F)

  • プロセス温度

    -20 °C ... 100 °C
    (-4 °F ... 212 °F)

  • プロセス圧力 (絶対圧力) / 最大過圧リミット

    真空 ... 1 MPa
    (真空 ... 145 psi)

  • 最小導電率

    10 µS/cm

  • 主要接液部

    1.4571、PTFE

  • プロセス接続

    G3/4

  • 通信 

    リレー

  • アプリケーション限界

    最小導電率監視

ドキュメント/マニュアル/ソフトウェア

アクセサリ / スペアパーツ

Nr
Order code
Specification
  • 20
    • Nr 20 Order code 52002593

      F6 アルミニウム カバー, 高, ガスケット

      O-リング EPDM. 用途: F6アルミニウムハウジング.

    • Nr 20 Order code 52002594

      カバー F10 PBT, 高, ガスケット

      O-リング VMQ. 用途: F10ポリエステルハウジング.

  • 30
    • Nr 30 Order code 52002590

      FEW24 エレクトロニックインサート AC/DC

      AC21...250V /DC20...200V 空引き防止監視センサ FTW360

  • 50
  • 後継機種