2 文字以上を入力して検索を開始してください。

TC62
Explosion-proof thermocouple thermometer

Product picture of thermocouple thermometer TC62 ©Endress+Hauser

Safe monitoring of process temperatures in challenging applications e. g. in the Oil & Gas industry

The robust thermometer is designed for use in demanding and safety relevant applications e.g. in the Chemical, Oil & Gas and Energy industry. The sensor is designed for use in a separate thermowell. An optional head transmitter with all common communication protocols makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. The modular design with a variety of options can be adapted to the measurement task.

クイック選択

推奨オプションから選択
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

または

個別のコンフギュレータ

すべての使用可能なオプションから選択を続行
  • 利点

    • Types of protection for use in hazardous locations: Intrinsic safety (Ex ia), flameproof (Ex d), non-sparking (Ex nA)

    • High degree of flexibility thanks to modular design with standard terminal heads as per DIN EN 50446 and customer-specific immersion...

  • アプリケーション

    • Heavy duty applications

    • Oil & Gas processing industry

    • Measuring range: –40 to 1 100 °C (–40 to 2 012 °F)

    • Protection class: IP68

機能と仕様

戻る

Details

  • 測定原理

    T用熱電対

  • 特性 / アプリケーション

    US 式

    モジュラータイプ

    高負荷アプリケーション用

    危険区域に対応

    ネジ込み接続

    ネック付

    要サーモウェル

  • サーモウェル / 保護管

    要サーモウェル

  • インサート / プローブ

    交換可能(プロセスの中断不要)

  • 保護管/インサート外径

    挿入口径

    6.0 mm(0.24'')

  • 最大浸漬長 要問合わせ

    最大 30,000.00 mm (1,181.10'')

  • 保護管/サーモウェルの材質

    定義されていません

  • コーティング(オプション)

    定義されていません

  • プロセス接続

    雄ネジ:

    NPT1/2"

  • 先端チップ部の形状

    ストレート

  • 表面粗さ Ra

    0.8 μm (31.5 μin.)

  • 測定温度レンジ

    タイプ K:

    -40 °C ...1,100 °C

    (-40 °F ...2,012 °F)

    タイプ J:

    -40 °C ...750 °C

    (-40 °F ...1,382 °F)

  • 最大プロセス圧力 (静的)

    20 °Cの時: 50 MPa (7,252 psi)

  • 精度

    class 1 IEC 60584準拠

  • 応答時間

    設定に依存

    t50 = 3 秒

    t90 = 7 秒

  • 組込型伝送器

    あり(4~20 mA;HART;PROFIBUS PA;FOUNDATIONフィールドバス)

  • 防爆認定

    ATEX II

    IECEx

    NEPSI

    EAC Ex

    防爆

  • 認証

    Gost 度量衡

    SIL(伝送器のみ)

ドキュメント/マニュアル/ソフトウェア

アクセサリ / スペアパーツ

Nr
Order code
Specification
  • C
  • A
  • B
    • Nr B Order code TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Nr B Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Nr B Order code TID10-

      Display for head transmitter TID10

      to plug on. Dot-Matrix measured value display. 12 DIP-switches buttom side. Settings: FF: Simulation, Write Lock. PA: Bus address, Write Lock. Compatible: TMT85, TMT84, TMT82.

    • Order code READWIN-

      Readwin 2000 Operation + Read. software

    • Order code TXU10-

      Configuration kit TXU10-

      for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.

    • Order code FXA195-

      Commubox FXA195

      Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.

  • D
    • Nr D Order code TA30H-

      Terminal Head TA30H

      Retainer for terminal block or head transmitter + optional display. Design: explosion proof. Cover: screwed, optional window. Material: aluminium. Coating: polyester powder-coating. Colour: body blue, cover grey. Ambient temp.: -50 150 oC (housing). Protection: IP66/68, NEMA 4X (housing). Protection Ex d/XP: IP66/67 (housing).

  • B
    • Nr B Order code TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Product being phased out, limited availability. Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr B Order code TMT182-

      iTEMP TMT182, Head Transmitter HART

      Product being phased out, limited availability. Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed.

    • Nr B Order code TMT82-

      iTEMP TMT82, Transmitter HART

      2-wire temperature transmitter. Dual universal sensor input. Galvanic isolation 2kV (input/output). Application: RTD, TC, Ohm and mV. ::Highly reliable due to drift detection and sensor back up. ::Optional also for safety critical applications by means of SIL 2/3 acc. to IEC61508.