Conductivity compact device
Smartec CLD132
Toroidal conductivity measuring system for hygienic applications
Smartec CLD132 is a measuring system for inductive conductivity in the food & beverage industry. The combination of a transmitter and a sensor is interference-free, easy-to-use and features a hygienic design that protects your products and processes from contamination. Moreover, Smartec CLD132 is equipped with a stainless steel temperature sensor that gives you an ultrafast temperature response for reliable measurement in separation applications.
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Measurement range
100 µS/cm - 2000 mS/cm
-
Process temperature
max. 140°C (max. 30 min.)
284°F (max. 30 min.) -
Process pressure
max. 12 bar (90°C)
(174 psi(194°F))
-
Quick selection
Individual configuration
-
Benefits
Engineered for quick temperature response
Hygienic design avoids recontamination
Suitable for cleaning-in-place (CIP) and sterilization-in-place (SIP)
Low risk of soiling due to encapsulated sensor
-
Field of application
Smartec CLD132 measures toroidal conductivity particularly in food & beverage applications, where a fast temperature response is needed, such as:
Alkaline/acid concentration control in remaking
Phase separation of product/water and product/product...
Documents / Manuals / Software
-
Technical Information Smartec S CLD132
Measuring system with inductive sensor for conductivity and
concentration measurement in the food industryTechnical Information (TI) -
Operating Instructions Smartec S CLD132
Conductivity Measuring System
Operating Instruction (BA) -
Operating Instructions SmarTec S CLD 132 Hart
Field Communication
with SmarTec S CLD132Operating Instruction (BA) -
Operating Instructions Smartec CLD132/134
PROFIBUS PA/DP
Operating Instruction (BA) -
Instructions for service kits Smartec S / CLD132
Special documentation
Instructions for service kits Smartec S / CLD132Special Documentation (SD) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.14.00Manufacturer Information (MI) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.05.00Manufacturer Information (MI) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.08.00Manufacturer Information (MI) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.06.00Manufacturer Information (MI) -
Juice application: CIP unit, Application 8
Meas. point 6: conductivity measurement CIP-return
Industry Solutions (SO)English -
Brewery application: CIP unit, Application 8
Meas. point 6: conductivity measurement CIP-return
Industry Solutions (SO)English -
Dairy application: CIP unit, Application 12
Meas. point 10: conductivity measurement CIP - feed
Industry Solutions (SO)English -
Brewery application: CIP unit, Application 12
Meas. point 10: conductivity measurement CIP - feed
Industry Solutions (SO)English -
Juice application: CIP unit, Application 12
Meas. point 10: conductivity measurement CIP - feed
Industry Solutions (SO)English -
Brewery application: Fermentation and Maturation, Application 14
Meas. point 11: conductivity measurement fermentation cellar
Industry Solutions (SO)English -
Dairy application: Pasteurisation, Application 7
Meas. point 6: phase separation of milk and water
Industry Solutions (SO)English -
Juice application: Juice pasteuriser, Application 9
Meas. point 8: phase separation in the pasteuriser
Industry Solutions (SO)English -
Dairy application: Cheese processing, Application 4
Meas. point 3: concentration control of the salt bath
Industry Solutions (SO)English -
Dairy application: CIP unit, Application 8
Meas. point 6: conductivity measurement CIP-return
Industry Solutions (SO)English -
Juice application: Mixing batch, Application 6
Meas. point 5: phase separation juice-water
Industry Solutions (SO)English -
GSD Single, GSD_EH_DP_AN_Smartec_0x153D_V01_50_DPLIB, 14.04.2014 (Analysi
s, Smartec S, 0x153D)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.50.00Language neutral -
GSD Single, GSD_EH_PA_AN_SmartecS_0x153E_0x01_0x01, 11.11.2016 (Analysis,
Smartec S, 0x153E)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_EH_PA_AN_SmartecS_0x151B_0x01_0x01, 11.11.2016 (Analysis,
Smartec S, 0x151B)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
GSD Single, GSD_EH_DP_AN_SmartecS_0x151A_0x01_0x01, 11.11.2016 (Analysis,
Smartec S, 0x151A)
PROFIBUS DP,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, PDM_PA_AN_SmartecS_0x153E_0x03_0x02, 07.01.2019 (Analysis, Smartec, 0x153E)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_AN_SmartecS_0x151B_0x01_0x01, 07.01.2019 (Analysis, Smartec, 0x151B)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, SmartecSDP_CLD132_V1_50, 28.10.2020 (Analysis, Smartec, 0x153D)
PROFIBUS DP,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, SmartecS_CLD132_V1_50, 21.10.2020 (Analysis, Smartec, 0x153E)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.153.348Language neutral -
DTM Single, SmartecS_CLD132_V1_11, 06.11.2020 (Analysis, Smartec, 0x0097)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
Measurement of electrical conductivity
(.mp4 format, 116 MB)
The conductivity of a liquid can be measured using the conductive or
toroidal measuring principles. This video shows what it is about and how
these measuring principles work.Animation01/14Polish -
Measurement of electrical conductivity
(.mp4 format, 70,7MB)
The conductivity of a liquid can be measured using the conductive or
toroidal measuring principles. This video shows what it is about and how
these measuring principles work.Animation01/14fr -
ConduMax H, ConduMax W, InduMax H, InduMax P, Liquisys Conductivity, Memosens, SmarTec, SmarTec S
Product Code: CLS82D-, CLS54D-, CLS54-, CLS50D-, CLS50-, CLS30-, CLS21D-, CLS21-, CLS19-, CLS16D-, CLS16-, CLS15D-, CLS15-, CLS13-, CLS12-, CLM253-, CLM223F-, CLM223-, CLD18-, CLD134-, CLD132-
Approval Number: EAEC RU D-DE.AD.07.B.01362/19MiscellaneousRussian -
SmarTec S, SmarTec, Sensor, Memosens, Liquisys Conductivity, Liquiline, InduMax P, InduMax H, ConduMax W, ConduMax H, Chloromax, ANALOG
Product Code: CLM253-, CLS12-, CLS13-, CLS15-, CLS15D-, CLS16-, CLS16D-, CLS19-, CLS21-, CLS21D-, CLS30-, CLS50-, CLS50D-, CLS54-, CLS54D-, CLS82D-, CYM290-, CLM223F-, CLM223-, CLD18-, CLD134-, CLD132-, CCS55D-, CCS51D-, CCS51-, CCS50D-, CCS50-, CCS241-, CCS240-, CCS142D-, CCS141-, CCS140-, CCS120D-, CCS120-
Region/Country: Russia (Declaration of Conformity)
Approval Number: EAEC RU D-DE.AD07.B.01363/19MiscellaneousRussian -
ConduMax H, ConduMax W, InduMax H, InduMax P, Liquisys Conductivity, SmarTec S
Product Code: CLS54-, CLS52-, CLS50-, CLS30-, CLS21-, CLS19-, CLS16-, CLS15-, CLS13-, CLS12-, CLM253-, CLM223-, CLD134-, CLD132-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: DE.C.31.004.A_66843MetrologyRussian
Accessories / Spare parts
-
-
Order code
Please order a standard sensor CLS52 for non- compact version
-
-
-
Nr 10 Order code 51501574
Kit CLD132/4 lower casing seperate vers.
-
-
-
Nr 20 Order code 51501576
Kit CLD132/4 lower casing compact vers.
-
-
-
Nr 40 Order code 51501577
Kit CLD132/4 housing cover complete
-
-
-
Nr 30 Order code 50062121
Round post installation for CYY101
-
-
-
Nr 120 Order code 51501589
Kit CLD132/4 PG glands+Goretex filter
-
-
-
Nr 121 Order code 51502282
Kit CLD132/4 M20 glands+Goretex filter
-
-
-
Nr 122 Order code 51502283
Kit CLD132/4 Contuit glands+Goretex
-
-
-
Nr 130 Order code 51501596
Kit CLD132/4 Sealings and small parts
-
-
-
Nr 140 Order code 51502382
Kit CLD132/4 Protection against contact
-
-
-
Nr 50 Order code 51501578
Kit CLD132 sensor compact version APV
-
-
-
Nr 51 Order code 51501579
Kit CLD132 sensor compact ver. Clamp 2"
-
-
-
Nr 52 Order code 51501580
Kit CLD132 sensor compact version G1.5"
-
-
-
Nr 53 Order code 51501581
Kit CLD132 sensor compact dairy fit.DN50
-
-
-
Nr 54 Order code 51501582
Kit CLD132 sensor compact vers. Varivent
-
-
-
Nr 55 Order code 51501583
Kit CLD132 sensor compact ver. Perlic 2"
-
-
-
Nr 56 Order code 51502279
Kit CLD132 sensor compact version SMS
-
-
-
Nr 51 Order code 71020489
Kit CLD134, version CS1, Spare sensor
-
-
-
Nr 53 Order code 71020487
Kit CLD134, version MV5, spare sensor
-
-
-
Nr 56 Order code 71020490
Kit CLD134, version SMS, spare sensor
-
-
-
Nr 54 Order code 71020491
Kit CLD134, version VA4, spare part
-
-
-
Nr 60 Order code 51501584
Kit CLD132/4 module box
-
-
-
Nr 61 Order code 51502280
Kit CLD132/4 module box for PA/DP
-
-
-
Nr 70 Order code 51502376
Kit CLD132 Main module 1 output
-
-
-
Nr 71 Order code 51502377
Kit CLD132 Main module 2 outputs
-
-
-
Nr 72 Order code 51502378
Kit CLD132 Main module 1 output / HART
-
-
-
Nr 73 Order code 51502379
Kit CLD132 Main module 2 outputs / HART
-
-
-
Nr 74 Order code 51502380
Kit CLD132 Main module Profibus PA
-
-
-
Nr 75 Order code 51502381
Kit CLD132 Main module Profibus DP
-
Nr 75 Order code 71134733
Kit CLD132: Central mod. PB DP; H/W 2.1x
Content: 1x Central module Profibus DP Module name: LSCP-DP qualified from H/W 2.10
-
-
-
Order code 71134735
Kit CLD13x: Terminal module for PB DP
Content: 1x Terminal module Profibus DP Module name : LSKB qualified for central mod. from H/W 2.10
-
-
-
Nr 80 Order code 71161133
Kit: MKIC Conductiv. transmitter Non-Ex
-
-
-
Nr 90 Order code 51501585
Kit CLD132/4 Power supply 100/115/230VAC
-
-
-
Nr 91 Order code 51501586
Kit CLD132/4 Power supply 24 V AC/DC
-
-
-
Nr 100 Order code 51501587
Kit CLD132/4 Terminal blocks 5+8+13 pol.
-
-
-
Nr 101 Order code 51502281
Kit CLD132/4 Terminal block set PA/DP
-
-
-
Nr 110 Order code 51501588
Kit CLD132/4 Flat ribbon cable 20 poles
-
-
-
Order code 51501643
Upgrade"Extended Functions"for Smartec
-
Order code CLS52-
Indumax CLS52
Conductivity, inductive sensor. Application: hygienic, food. CIP control, phase separation. Process temp. max 125oC (short 140oC). Process pressure max. 16 bar (90oC). Sensor material: PEEK. Quality certificate.
-
Order code CLS54-
Indumax CLS54
Conductivity, inductive sensor Application: hygienic Food, pharma CIP control, phase separation Process temp. max.120oC (short 150oC) Process pressure max.12 bar (20oC) Sensor material: PEEK Quality certificate
-
-
Predecessor