Horn antenna: High precision measurement for for storage tanks up to 20 m (65ft) Parabolic antenna: High precision measurement for free space applications up to 40 m (131 ft)
Supply / Communication
4-wire (HART)
Frequency
K-band (~26 GHz)
Accuracy
+/- 1 mm
Ambient temperature
Standard: -40°C...80°C (-40°F...176°F) For calibration to regulatory standards: -25°C...60°C (-13°F...131°F)
Process temperature
-40°C...200°C (-40°F...392°F)
Process pressure / max. overpressure limit
Horn: Vacuum...16 bar (232 psi) Parabolic: Vacuum...6 bar (87 psi) Use of UNIflange: Vacuum...1 bar (14.5 psi)
Main wetted parts
316L
Process connection
Horn Antenna: DN100, DN150 Flange UNIFlange DN150, DN200, DN250 Parabolic antenna: UNIflange with Top Target positioner DN200, DN250 For dk value < 1.9, contact Endress+Hauser
Communication
4...20 mA HART
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, NEPSI
Application limits
Maximum measuring range is dependent on the tank form and/or application Strong condensate or build-up formation FMR53x Existing stilling wells with non-ideal measuring conditions FMR532
Level-Radar
Continuous level transmitter for continuous and non-contact precision
level measurement. For custody transfer andinventory control
applications with NMi and PTB approvals.
Level-Radar Continuous level transmitter for continuous and non-contact precision level measurement. For custody transfer andinventory control applications with NMi and PTB approvals.
Level-Radar Continuous level transmitter for continuous and non-contact precision level measurement. For custody transfer andinventory control applications with NMi and PTB approvals.