仕様一覧
-
Measured variables
CH4, CO, CO2, H2, H2O, N2O, NH3, NO, NO2, O2, SO2
Hydrocarbons (e.g. C2H2), halogenated hydrocarbons (e.g. CH2Cl2) and other gases upon request -
Ambient temperature range
+5 °C ... +45 °C
-
Hazardous area approvals
S715 Ex:
ATEX II 3G Ex nR IIC T6 Gc
Without intrinsically safe measured value outputs
ATEX II 3G Ex nR [ib] IIC T6 Gc
With intrinsically safe measured value outputs
S720 Ex / S721 Ex:
ATEX II 2G Ex db ia IIC T6 Gb
Without intrinsically safe measured value outputs
ATEX II 2G Ex db ia [ia] IIC T6 Gb
With intrinsically safe measured value outputs
アプリケーション
With the modular gas analyzer S700, a customer-specific and tailor-made measuring device can be put together for almost every application. Various analyzer modules for the measurement of well over 60 gases, and different housing variants offer comprehensive and individually tailored combination options.
Cooling gas monitoring of turbo generators
CO measurement for coal mill monitoring
H2 purity measurements in pressure swing adsorption systems
CO2 monitoring in natural gas during natural gas processing
Device properties:
Various analyzer modules are available: UNOR (NDIR), MULTOR (NDIR), OXOR-E (electrochemical O2), OXOR-P (paramagnetic O2), THERMOR (thermal conductivity)
Over 60 measuring components to choose from
Different housing variants
Up to three analyzer modules in one housing
利点
Simple application-specific configuration thanks to modular design
Can also be used in Zone 1 and Zone 2 (ATEX) explosion-hazardous areas
Automatic readjustment using test gas or calibration cell
Integrated self-monitoring and error analysis
Process monitoring for the safety and quality of manufacturing processes and products by measuring flammable gases and explosive gas mixtures in zones 1 and 2
Reliable remote control and integration into distributed control systems thanks to optional equipment with various interface converters

FLEX セレクション | 技術的卓越性 | シンプルさ |
---|---|---|
Fundamental セレクション 基本的な測定要件に対応 |
技術的卓越性
|
シンプルさ
|
Lean セレクション コアプロセスの要件に対応 |
技術的卓越性
|
シンプルさ
|
Extended セレクション 革新的な技術でプロセスを最適化 |
技術的卓越性
|
シンプルさ
|
Xpert セレクション 最も困難なアプリケーションにも対応 |
技術的卓越性
|
シンプルさ
高い柔軟性 |
-
測定原理
NDIR spectroscopy, Electrochemical cell, Paramagnetic dumbbell principle, Thermal conductivity measurement
-
Measured variables
CH4, CO, CO2, H2, H2O, N2O, NH3, NO, NO2, O2, SO2
Hydrocarbons (e.g. C2H2), halogenated hydrocarbons (e.g. CH2Cl2) and other gases upon request -
Performance-tested measurands
CO, NO, O2, SO2
-
Process pressure
Hosed internal gas paths:–20 kPa ... 30 kPa
Piped internal gas paths:–20 kPa ... 100 kPa
With “OXOR-E” analyzer module:–20 kPa ... 30 kPa
S720 Ex/S721 Ex:–20 kPa ... 10 kPa -
Ambient temperature range
+5 °C ... +45 °C
-
Ambient humidity
≤ 95 %
Relative humidity; non-condensing -
Conformities
Industrial Emissions Directive (IED)
CCEP
U.S. EPA conform
China's EPA compliant -
Hazardous area approvals
S715 Ex:
ATEX II 3G Ex nR IIC T6 Gc
Without intrinsically safe measured value outputs
ATEX II 3G Ex nR [ib] IIC T6 Gc
With intrinsically safe measured value outputs
S720 Ex / S721 Ex:
ATEX II 2G Ex db ia IIC T6 Gb
Without intrinsically safe measured value outputs
ATEX II 2G Ex db ia [ia] IIC T6 Gb
With intrinsically safe measured value outputs -
Degree of protection
IP65 / NEMA 7
-
Product safety
CE, CSA (option)
-
-
コンピテンスカタログ(CP)
Emission Monitoring Solutions – broad instrument portfolio and longstanding experience
-
コンピテンスカタログ(CP)
英語版 - 01/2025An overview brochure about emission monitoring, their measuring
principles and technologies, global requirements and services, a
selection guide and the measuring devices at a glance言語:
英語
バージョン:
01/01/2025
ファイルサイズ:
4.5 MB
ファイル名:
8029975_CP_Emission_Monitoring_Solutions_en_V3-0_2025.01_EHS.pdf
-
-
-
イノベーション(IN)
S700 – extractive gas analyzers
-
イノベーション(IN)
英語版 - 03/2025Tailor-made gas analysis for process and emission monitoring
言語:
英語
バージョン:
24/03/2025
ファイルサイズ:
2.9 MB
ファイル名:
8030000_IN_S700_en_V4-0_2025.01_EHS.pdf
-
推奨オプションから選択
-
-- selected coding-- selected label99.999,00<%label%>
-
他のオプションをお探しですか? 個別のコンフィギュレータ を使用して続行してください。
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
他のオプションをお探しですか? 個別のコンフィギュレータ を使用して続行してください。
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD図面 CAD図面
- CAD図面
-
1個単位の価格
-
<%range%><%price%>
-
- オプションのアドオン