Conductive
Point level detection
Double rod probe 11362Z

Probe 11362Z ©Endress+Hauser

High resistant probes for corrosive liquids in plastic vessels

The 11362Z is a high resistant probe for applications requiring accurate point level detection or overfill prevention in plastic vessels or vessels made of non-conducting material. The two-point control can be carried out in vessels with electrically conducting walls.

  • 利点

    • Reliable and safe measurement

    • Safe measurement even for applications in explosion hazardous area

    • Variable process connections for various applications

  • アプリケーション

    For vessels made of plastic or non-conducting material. For applications in explosion hazardous areas, in waste water plants, which are sometimes regarded as Zone 0 or as overfill prevention for water-polluting liquids.

    • Process connections: Threads and...

Details

  • 測定原理

    導電性

  • 特性 / アプリケーション

    2 本電極プローブ、ハイクラス測定物接液部付き

  • 電源 / 通信

    リレー

  • 周囲温度

    -20 °C ... 80 °C
    (-4 °F ... 176 °F)

  • プロセス温度

    -40 °C ... 150 °C
    (-40 °F ... 302 °F)

  • プロセス圧力 (絶対圧力) / 最大過圧リミット

    真空 ... 3 MPa
    (真空 ... 435 psi)

  • 最小導電率

    20 µS/cm

  • 主要接液部

    PTFE、PFA、SUS316Ti相当、アロイ B/C4、チタン、タンタル、モネル

  • プロセス接続

    G 1 1/2A
    NPT1 1/2"
    フランジ DIN /ASME

  • センサ長

    0.1m ... 4m

  • 通信 

    リレー

  • 規格適合証明書/認証

    ATEX, NEPSI

  • 安全認証

    オーバーフロー防止 WHG

  • コンポーネント

    変換器: FTW325

  • アプリケーション限界

    最小導電率監視

ドキュメント/マニュアル/ソフトウェア

アクセサリ / スペアパーツ

Nr
Order code
Specification